Lennox nomenclature model number.

The model and serial numbers for your cooling system can be found on the nameplate or sticker, located near the service panel. The nomenclature sticker should have a white background with black letters.

Lennox nomenclature model number. Things To Know About Lennox nomenclature model number.

Elite ELS Series, 15 Ton Commercial Air Conditioner, 12 IEER, 208-230 VAC 3 Ph 60 Hz, ELS180S4DS1Y. Cat # : 21C45. Model/Part # : ELS180S4DS1YService Literature. G40UH (X) series units are mid−efficiency gas furnaces. used for upflow or horizontal applications only, manufac-. tured with Lennox Duralok Plus heat exchangers formed of. aluminized steel. G40UH (X) units are available in heating. capacities of 44,000 to 154,000 Btuh and cooling applica-. tions up to 5 tons.NOTE — Due to Lennox' ongoing committent to quality, Specifications, Ratings and Dimensions subject to change without notice. 1994 Lennox Industries Inc. ... CHP16H-261 model is available with single phase voltage. The CHP16-413-513-653 models are available with a choice of thermostat ... number of guards are furnished per order number. ...7 Unit Diagram. Download this manual. SERVICE. The HS26 is a high efficiency residential split−system con. densing unit which features a scroll compressor. Early. model HS26 units (−261,−311,−411, and −461) are available. in sizes ranging from 2 …The Goodman Air Conditioner model number is usually contained in 12 digit code. The model number includes three digits starting with zero for the nominal cooling capacity of the unit. The three-digit number shows the total capacity of the unit. We can measure it in Thermal British units. You can find the tonnage of your AC based on the …

The serial number for your Lennox air conditioner is printed in black on a white background on the data plate, or nameplate, which is found on the unit's exterior near the service panel. Lennox air conditioner serial numbers are composed of 10 characters that follow a specific pattern. That pattern is four digits, one letter, and five more digits.You can also view G20Q3E-75-4 parts diagrams and manuals, watch related videos or review common problems that may help answer your questions to get started on fixing your Furnace model. For additional assistance, please contact our customer service number at 1-800-269-2609, 24 hours a day, seven days a week or send us a message using the live ...

Title: us_ehb_gcs16lg_1193 Author: awh Subject: engineering handbook Created Date: 4/26/2001 3:21:26 PMCondensate Drain Heat Cable Kits. − Selflimiting wattage heat cable prevents condensate drain from freezing in unconditioned areas. − Available in 6, 24 or 50 ft. (1.8, 7.3, or 15.2 m) lengths. − See specifications table for order number. Heat Cable Tape: − 66 ft. (20 m) length, 1/2 in. (13 mm) wide fiberglass.

Back-of-the-napkin business model is slang for a draft business model. Entrepreneurs sometimes jot down ideas on any available surface - including napkins. Slang for a draft busine...ADP evaporator coils are uniquely designed to save customers time on installation while ensuring a leak-free system. We offer custom solutions to leverage local market differentiation and growth opportunities. Out-of-the-box installation. SKU optimization. Industry-exclusive Microban® anti-microbial product protection.Solar. SunSource® Commercial Energy System5. Factory. Field. Visit us at www.lennox.com For the latest technical information, www.lennoxcommercial.com Contact us at 1-800-4-LENNOX ©2019 Lennox Industries, Inc. (14G47) 2/19 PC92164. 92164_energence_RTU_qr_guide.indd 2. 3/4/19 9:30 AM.At every turn, the ML296V gas furnace is designed to be the most energy-efficient furnace in its class. A variable-speed fan keeps temperature swings to a bare minimum. Two-stage heating saves gas by adjusting the flame size based on demand. Energy-Efficient Design - With a 96% efficiency rating, the ML296V gas furnace uses 2/3 less energy than ...MODEL NUMBER IDENTIFICATION. ELA 6 to 20 Ton Air Handlers / Page 2 180-240 Models 072-090-120-150 Models FEATURE HIGHLIGHTS 1. Multi-Circuit, Copper Tube Coil 2. Expansion Valve ... • Suitable for application with Lennox 6 to 20 ton ELS air conditioners or 7.5 to10 ton ELP heat pump outdoor units

Lennox Model Number Nomenclature is a crucial topic that must be grasped by everyone, ranging from students and scholars to the general public. The book will furnish comprehensive and in-depth insights into Lennox Model Number Nomenclature, encompassing both the fundamentals and more intricate discussions. The book is structured into several ...

Lennox® packaged rooftop units represent some of the most innovative technology in the market. Combining industry-leading efficiency with fast, easy installation and service, Lennox continues to offer reliable systems that deliver exceptional comfort in commercial buildings. ... Model L™ Tonnage. 3-25 TONS. SEER/IEER. Up To 22.5/23.3. EER ...

The LGA / LCA / LHA 13, 15, 17.5, 20 and 25 ton (46, 53, 62, 70 and 88 kW) units are configure to order units (CTO) with a wide selection of factory installed options. The LGA180/210/240/300S gas/electric packaged rooftop units are available in 260,000 Btuh or 470,000 Btuh (76.2 kW or 137.7 kW) heating inputs.On other Lennox products the plate is mounted on the outside of unit. The sequence of letters and digits in the Lennox model number reflects specific information about the unit. The figures below analyze two typical model numbers. HS26-060-1P HS26 is the Series, 060 is the Capacity, 1P (1) is the Dash Number and (P) is the Power Characteristics.Lennox CB17 and CBH17 model blower−coil units, de-signed for indoor applications only, are available in two models; CB17 series with up−flow supply air discharge or ... Model Number CB17-95V CBH17-95V CB17-135V CBH17-135V CB17-185V CBH17-185V CB17-275V CBH17-275V Nominal Cooling Capacity Tons (kW) 7-1/2 (26) 10 (35) 15 (53) 20 (70)3.1 Model Numbering Systems Introduction All Lennox product is set up with a systematic coding system for both model numbers and serial numbers. Unit model number (including any dash ... tonnage to the Btuh capacities found in model numbers. Old Nomenclature BTU = TONS BTU = TONS -14 = 1 ton -95 = 7½ tons -21 = 1½ tons -135 = 10 tonsEnlight™ rooftop units, powered by the Lennox® CORE Control System, create a bright future through a highly energy-efficient and environmentally sustainable design. Comprehensive configurations meet a wide range of applications, making it the most flexible product line Lennox has to offer. Overview. Features. Product Literature.

Generally, the first four digits are crucial for determining the manufacture date. The first two digits represent the year, while the next two digits represent the month of production. For example, if your serial number starts with "1709," it means your air conditioner was manufactured in September of 2017. To decode the serial number and ...On other Lennox products the plate is mounted on the outside of unit. The sequence of letters and digits in the Lennox model number reflects specific information about the unit. The figures below analyze two typical model numbers. HS26-060-1P HS26 is the Series, 060 is the Capacity, 1P (1) is the Dash Number and (P) is the Power Characteristics.M = 380/420V-3 phase-50hz. 10.5 to 21 kW (3 to 6 Ton) Net Cooling Capacity - 9.2 to 19.2 kW (32 400 to 65 500 Btuh Gas Input Heat Capacity - 16.7 to 38.7 kW (57 000 to 132 000 Btuh) LGH 10.5 TO 21 KW ROOFTOP UNITS. MODEL NUMBER IDENTIFICATION. COMMERCIAL PRODUCT SPECIFICATIONS.Lennox, Air Conditioner, T CLASS, 4 Ton, 14 SEER, 1 Stage, 208-230 VAC 3 Ph 60 Hz, TSA048S4N44Y. Cat # : 14V84. Model/Part # : TSA048S4N44Y%PDF-1.5 %âãÏÓ 280 0 obj > endobj 300 0 obj >/Filter/FlateDecode/ID[1BBBE75283E426F2E7A4E65AA48DEFC4>]/Index[280 39]/Info 279 0 R/Length 100/Prev 892984/Root 281 ...Lennox, Air Conditioner, T CLASS, 4 Ton, 14 SEER, 1 Stage, 208-230 VAC 3 Ph 60 Hz, TSA048S4N44Y. Cat # : 14V84. Model/Part # : TSA048S4N44YMerit® Series. 14HPX Heat Pump. Economical, environmentally responsible home cooling and heating. The temperature always feels just right inside with the budget friendly 14HPX-024-230. Precision engineered with quality components, this heat pump allows customers to enjoy exceptional comfort, without the worry of high utility bills.

model number kca/kga 156h4b/m kca/kga 180h4b/m kcb/kgb180s4b kcb/kgb180s4m kca/kga 210h4b/m kcb/kgb210s4b kcb/kgb210s4m k c a/k ga 240h4b/m kcb/kgb240s4b kcb/kgb240s4m kcb/kgb 300s4b/m blower type cav/msav cav/msav cav/msav cav/msav cav/msav cav/msav cav/msav cav/msav net cooling capacity (btuh) 150,000 172,000 176,000 194,000 200,000 230,000 ...Number and size of filters (in.) Optional Roof Mounting Frame (used with RDE16-41 only) Optional Economizer Dampers Model No. 3 position Modulating Number and size of filters (in.) Optional Ceiling Supply and Return Air Diffusers Step Down Flush Transition 50,000 75,000 38,000 50,000 38,000 75.0%/75.0% 7.8 24,600 2620 10.0 9.4 3 lbs. 3 oz. 9 x ...

Lennox Model Number Nomenclature lennox-model-number-nomenclature 2 Downloaded from www.50storiesfortomorrow.ilfu.com on 2019-04-14 by guest Radiology of Australian Mammals Larry Vogelnest 2015-06-15 How to interpret radiographs of native mammals in order to make informed decisions on diagnosis, prognosis and treatment.Breakdown the model number to know what the model number tells you. The most important is knowing the SEER rating and Tonnage (size).This is how to decode it: Bryant unit model: #561CJ048. 561 - series (10 SEER R22 unit) 048 - 4 ton nominal cooling capacity. Model Number: #355BAV060100. 355 - series. B - model (multipoise)You may see revision numbers as high as 14 or even 18. The revision number is very important in repair part identification as a -1 unit may have a different motor than a -8 would. Phase or Voltage Requirement. The P indicates the phase or voltage the unit requires. P equals single phase 208-230 volt where a Y would equal 3 phase 208-230 volt or ...You may see revision numbers as high as 14 or even 18. The revision number is very important in repair part identification as a -1 unit may have a different motor than a -8 would. Phase or Voltage Requirement. The P indicates the phase or voltage the unit requires. P equals single phase 208-230 volt where a Y would equal 3 phase 208-230 volt or ...The Lennox CB29M and CB30M Elite. series blower coil. units are designed for installation with a matched remote. outdoor unit and optional field−installed electric heat. The. blower coil units are for indoor installation only. The CB29M and CB30M units, designed for multi−position-. al installations, are completely assembled at the factory.EL296UHV(X) series units are 90% efficiency gas furnaces used for upflow or horizontal applications only, manufac­ tured with Lennox Duralok heat exchangers formed of aluminized steel. EL296UHV(X) units are available in heat­ ing capacities of 44,000 to 132,000 Btuh and cooling ap­ plications up to 5 tons.Table 7.2.5 Lennox Model Number Description G 40 UH 24 A 045 X Unit Type Series Configuration Nominal Add-On Cooling Capacity Cabinet Width Heating Input (btu/h) CA emission requirements G = Gas Furnace 40 = Merit Series 80% 50 = Elite 80% 60 = 2-stage 80% UH = Upflow/Horizontal DF = Downflow/Horizontal 24 = 2 Tons 36 = 3 Tons

Manuals and User Guides for Lennox KGA092 Series. We have 2 Lennox KGA092 Series manuals available for free PDF download: Service Literature, Installation Instructions Manual . Lennox KGA092 Series Service Literature (45 pages) Units 7.5 to 12.5 ton, 26.3 to 42 kW. Brand: Lennox ...

ML195UH. MERIT®SERIES. Upflow / Horizontal. Bulletin No. 210591 March 2019. Supersedes September 2018. AFUE - 95% Input - 44,000 to 132,000 Btuh Nominal Add-on Cooling - 2 to 5 Tons. MODEL NUMBER IDENTIFICATION. ML 1 95 UH 070 X P 36 B. Unit Type ML = Merit®Series Stages 1 = One-Stage Nominal Gas Heat InputBlower.

Lennox Furnace Model Number Nomenclature - romaheating.caNumber and size of filters Horizontal (end) 87L95 − (1) 14 x 25 x 1 in. (356 x 635 x 25 mm) 87L96 − (1) 18 x 25 x 1 in. (457 x 635 x 25 mm) Side Return Single (44J22) or Ten Pack (66K63) − (1) 16 x 25 x 1 in. (406 x 635 x 25 mm) EZ Filter Base Catalog Number − Shipping Weight 73P55 − 6 lbs. (3 kg) 73P56 − 7 lbs. (3 kg)Also called the abnormal earnings valuation model, the residual income model is a method for predicting stock prices. Also called the abnormal earnings valuation model, the residua...Created Date: 5/2/2002 3:07:14 PMDecoding Lennox Model Numbers could not be easier than with the HVAC Decoder App installed on your smartphone. This app will also handle the modern style Lennox model numbers for Furnaces, Evaporator Coils, Heat Pumps, Package units, and more. Take this old model number HS18-311-4P for example. Nothing in it gives you a hint about the cooling ...View and Download Lennox LGA Series unit information online. LGA Series air conditioner pdf manual download. ... 30 Ton Data Model No. 360H2B 360H4B 360H2V 360H4V Efficiency Type High High High High Blower Type Constant Air Constant Air Variable Air Variable Air ... The flame should be stable without flashback under part number 31B2001. See ...Number of rows 3 3 3 3 Fins per inch (m) 14 (551) 14 (551) 14 (551) 14 (551) Condensate Drain − number & size (1) 1 in. NPT coupling Expansion device type Balanced Port Thermostatic Expansion Valve, removeable power head 3 Indoor Blower and Drive Selection Nominal motor output 5 hp (3.7 kW) − 7.5 hp (5.6 kW) − 10 hp (7.5 kW)Model Number Identification M WM A 012 S 4 - 1 P Unit Type WM = Wall-Mounted Non-Ducted Unit Series Type M = Mini-Split Voltage L = 115V-1 phase-60hz P = 208/230V-1 phase-60hz WALL-MOUNTED INDOOR UNITS Cooling Efficiency S = Standard Efficiency Major Design Sequence A = 1st Generation B = 2nd Generation Nominal Cooling Capacity 009 = .75 tonsNumber and size of filters Horizontal (end) 87L95 − (1) 14 x 25 x 1 in. (356 x 635 x 25 mm) 87L96 − (1) 18 x 25 x 1 in. (457 x 635 x 25 mm) Side Return Single (44J22) or Ten Pack (66K63) − (1) 16 x 25 x 1 in. (406 x 635 x 25 mm) EZ Filter Base Catalog Number − Shipping Weight 73P55 − 6 lbs. (3 kg) 73P56 − 7 lbs. (3 kg)

On paper, crowdsourced innovation makes a lot of sense: If two heads are better than one, why not 20,000? Surely, some of those outsiders will have fresh solutions to your problem....The second two digits of the serial number are the year of manufacture for Lennox units. This unit was manufactured in 2010. To find out the age of another brand of air conditioner or heat pump, go to How do I determine the age of my air conditioner?, which has a listing of all major manufacturers and links to instructions for decoding their ... − Refer to Lennox Equipment Limited Warranty certificate for specific details. Refrigeration System − All models include: check/expansion valve, reversing valve, filter drier, suction and liquid line service gauge ports, high pressure switch (manual reset) and full refrigerant charge. Instagram:https://instagram. bmv upper sandusky ohlyrics of barney theme songround 6 results 2023 nfrpneumonia ati system disorder A variable-speed fan keeps temperature swings to a bare minimum. Two-stage heating saves gas by adjusting the flame size based on demand. Relax. Save money every month. With a 96% efficiency rating, the ML296V gas furnace uses 2/3 less energy than competitive single-speed units so you pay for perfectly heated air, not wasted energy. quick suggestion crosswordhotels on south michigan avenue chicago Temperature set point [85, 100, 115 or 130°F (30, 38, 46 or 54°C)] is selected by use of a jumper pin on the EHC control board. ECB29EH-9CB, -12.5CB, -15CB and -20CB heaters are equipped with circuit breakers for overload and short circuit protection. Factory provided and field mounted in electric heat unit. healed jigger holes The ML14XC1 comes with a 5-year limited warranty on the compressor and all remaining covered components.**. *The cooling efficiency rating for air conditioners is Seasonal Energy Efficiency Ratio, or SEER. The higher the SEER, the better the energy performance, and the more you save. ** Covered components may be eligible to receive a 10-year ...Lennox model numbers 14= 1 ton 21= 1-1/2 ton 26= 2 ton 31= 2-1/2 ton 41= 3 ton 46= 3-1/2 ton 51= 4 ton 65= 5 ton So, your unit is a two ton model. The HS stands for high side, HP for heat pump. The next two numbers are the series of unit, they generally work up as they introduce new models. Then a dash and the next two digits which are …